userdoc:board_pcengines_apu

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
userdoc:board_pcengines_apu [2014/08/18 07:52]
abelbeck
userdoc:board_pcengines_apu [2019/07/25 07:44]
abelbeck
Line 3: Line 3:
 !!Note: AstLinux 1.1.7 or later is required!! !!Note: AstLinux 1.1.7 or later is required!!
  
-!!Note: PC Engines APU1 BIOS update is optional!!+!!Note: PC Engines APU1 will be discontinued in 2017, replaced by **[[userdoc:board_pcengines_apu2|APU2]]**!!
  
-**Board Specifications:**  [[http://pcengines.ch/apu1c.htm|apu1c]]+**Board Specifications:**  [[http://pcengines.ch/apu1d.htm|apu1d]]
  
 **AstLinux Board Type:** **AstLinux Board Type:**
  
-  * "geni586-serial" (19200 115200 baud serial console)+  * "genx86_64-serial" (Serial Console: ''19200'' baud for AstLinux 1.2.10 and earlier, ''115200'' baud for AstLinux 1.3.0 and later)
  
 **Complete System Recommended Options:** **Complete System Recommended Options:**
Line 18: Line 18:
   * Storage: mSATA SSD (or SD Card via USB internally, not recommended)   * Storage: mSATA SSD (or SD Card via USB internally, not recommended)
   * Included:   * Included:
-      * 2GB (apu1c) or 4GB (apu1d4) DRAM+      * 2GB (apu1d) or 4GB (apu1d4) DRAM
  
 **Total System Power:**  8 Watts when idle. **Total System Power:**  8 Watts when idle.
 +
 +**Performance:**  59.1 secs. (Single-core test, lower is better)
 +
 +  time ( echo "scale=3456; 4*a(1)" | bc -l )
  
 **Configuration:** **Configuration:**
Line 43: Line 47:
 **Serial Console COM Port:** **Serial Console COM Port:**
  
-The board type of "geni586-serial" defaults to a 19200 baud serial console, unfortunately the PC Engines's BIOS is fixed at 115200 baud, so if you want to view the BIOS console you must change the AstLinux serial console speed to match at 115200 baud.  After+!!Note ->!! Skip this section for AstLinux 1.3.0 and later, which uses a ''115200'' baud rate. 
 + 
 +For AstLinux 1.2.10 and earlier, the board type of "genx86_64-serial" defaults to a 19200 baud serial console, unfortunately the PC Engines's BIOS is fixed at 115200 baud, so if you want to view the BIOS console you must change the AstLinux serial console speed to match at 115200 baud.  After
 **[[userdoc:new-install#persistent_storage_options_gui|persistent storage]]** **[[userdoc:new-install#persistent_storage_options_gui|persistent storage]]**
 has been configured, from the CLI issue the following command: has been configured, from the CLI issue the following command:
Line 59: Line 65:
   reboot=bios   reboot=bios
      
-!!Note ->!! This reboot issue is fixed in the beta PC Engines APU1 BIOS apu140708 (8/7/2014).+!!Note ->!! This reboot issue is fixed in the beta PC Engines APU1 BIOS apu140708 (2014-07-08).
  
 \\  \\ 
  • userdoc/board_pcengines_apu.txt
  • Last modified: 2019/07/25 07:44
  • by abelbeck