userdoc:board_lanner_fw-7541d

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
userdoc:board_lanner_fw-7541d [2016/06/06 15:30]
abelbeck
userdoc:board_lanner_fw-7541d [2019/07/24 21:24] (current)
abelbeck
Line 7: Line 7:
 **AstLinux Board Type:** **AstLinux Board Type:**
  
-  * "genx86_64-serial" (19200 baud serial console)+  * "genx86_64-serial" (Serial Console: ''19200'' baud for AstLinux 1.2.10 and earlier, ''115200'' baud for AstLinux 1.3.0 and later)
  
 **Complete System Recommended Options:** **Complete System Recommended Options:**
Line 21: Line 21:
 **Total System Power:**  15 Watts when idle. **Total System Power:**  15 Watts when idle.
  
-**Performance:**  48.secs. (Maximum Measured OpenVPN: 71 Mbps)+**Performance:**  49.secs. (Single-core test, lower is better)
  
-  openvpn --genkey --secret /tmp/secret +  time ( echo "scale=3456; 4*a(1)" | bc -l )
-  time openvpn --test-crypto --secret /tmp/secret --verb 0 --tun-mtu 20000 --cipher aes-256-cbc+
  
 **Configuration:** **Configuration:**
Line 101: Line 100:
  
 First, configure your serial terminal program to support ANSI color and 115200 baud.  If you are using minicom be sure to add the ' ''-c on'' ' option to the minicom command line, otherwise the ANSI colors will not be distinguishable in the BIOS Setup screen. First, configure your serial terminal program to support ANSI color and 115200 baud.  If you are using minicom be sure to add the ' ''-c on'' ' option to the minicom command line, otherwise the ANSI colors will not be distinguishable in the BIOS Setup screen.
 +
 +!!Note ->!! Leave ''Serial Port Mode -> 115200 8,n,1'' for AstLinux 1.3.0 and later.
  
 Second, on startup as soon as you hear the beep, type <TAB> to enter the BIOS Setup, go to the "Advanced" -> "Remote Access Configuration" .  Make the following changes... Second, on startup as soon as you hear the beep, type <TAB> to enter the BIOS Setup, go to the "Advanced" -> "Remote Access Configuration" .  Make the following changes...
Line 113: Line 114:
 {{:userdoc:lanner_fw-7541d-remote-bios.png?nolink|Remote Access BIOS}} {{:userdoc:lanner_fw-7541d-remote-bios.png?nolink|Remote Access BIOS}}
  
-Finally, save the above BIOS changes, reboot, and reconfigure you serial terminal program to 19200 baud, this will match what AstLinux expects.+Finally, save the above BIOS changes, reboot, and reconfigure you serial terminal program if you changed the baud rate.
  
 **Photos:** **Photos:**
  • userdoc/board_lanner_fw-7541d.1465245031.txt.gz
  • Last modified: 2016/06/06 15:30
  • by abelbeck